AC-DC Power Modules
Mechanical & Connection Details (cont.)
TMP30 Models for PCB Mount
TMP30 Models for Chassis Mount
Pin-out
Pin Single Dual Dual Triple
sym. asym.
1 AC(N) AC(N) AC(N) AC(N)
2 AC(L) AC(L) AC(L) AC(L)
3 +Vout Vout1 +Vout2 Vout2
4 No pin No pin +Vout1 +Vout1
5 -Vout Comm. -Vout2 Comm.
6 No pin No pin -Vout1 -Vout1
7 N/C Vout2 N/C Vout3
Connections
Pin Single Dual Dual Triple
sym. asym.
1 AC(N) AC(N) AC(N) AC(N)
2 AC(L) AC(L) AC(L) AC(L)
3 +Vout Vout1 +Vout2 Vout2
4 N/C N/C +Vout1 +Vout1
5 -Vout Comm. -Vout2 Comm.
6 N/C N/C -Vout1 -Vout1
7 N/C Vout2 N/C Vout3